SEIKOM Electronic - TÜV-certified quality for over 30 years. Trust in our experience.

30 years of experience | TÜV-tested quality | ISO9001-certified | Shipping within 24 hours | Contact us now

New white paper
Now available: Free white paper on our latest measurement and control technologies!
Download here!

RLSW9 volumetric flow meter for measuring the flow of gases up to 350°C

SKU: 1362F3M8/50

Description

Volume flow and air velocity measuring device with linear analog output in control quality (0 ... 10 V & 4 ... 20 mA) and switch

Suitable for media temperatures up to 350°C

Measured value display via LCD, LED strip and alarm light

Freely scalable measuring range m/s, m³/h, l/min

S ensitive and fast airflow detection up to 30 m/s, optionally up to 200 m/s

Sensor available in nickel-plated brass (standard), stainless steel or Teflon

Exemplary areas of application: Measurement and control of air flows, building technology, PLC, filter monitoring, extraction and extruder systems, exhaust gases and test benches

Device type
Media temperature
Immersion depth
€389,90
Shipping will be charged at checkout.

Operating instructions EN: Download

Operating instructions EN: Download

Specification

  • Medium
    Gases
  • Device type
    Compact flow device
  • Device type
    Compact device including sensor (permanently mounted), Compact device including sensor (remote)
  • Flow measuring range
    0,1 ... 30 m/s (optionally available up to 200 m/s)
  • Flow measurement accuracy
    ±5% of full scale value, Reproducibility ±2% of full scale value
  • Display
    LCD with backlight that can be switched off, yellow LED at flow velocities > switching point, green LED during operation, 10 red LEDs for the flow rate in 10% increments
  • Switching point
    Stepless adjustment (software or potentiometer)
  • Protection class evaluation unit
    IP66
  • Sensor protection class
    IP67
  • Special features
    linear analog output flow velocities up to 200 m/s measurable, acknowledgeable alarm, steel housing available on request, adjustable start-up delay 0 ... 300 s velocity dimensions: m/s, l/min, m³/h, linear analog output can be used up to 350°C media temperature, flow velocities up to 200 m/s measurable, steel housing available on request, acknowledgeable alarm, adjustable start-up delay 0 ... 300 s, velocity dimensions: m/s, l/min, m³/h
  • Output signal
    Switching output, analog output
  • Switching output specification
    1 NO contact (closes/opens with flow, adjustable)
  • Signal output sensor break
    Fault-specific error codes in the LCD, 4 mA, Relay drops out
  • Signal output Sensor short circuit
    Fault-specific error codes in the LCD, 4 mA, Relay drops out
  • Relay output specification
    1 NO contact (closes/opens with flow, adjustable)
  • Immersion depth
    50, 130, 165, 300, 400, 500, Special lengths on request
  • Process connection
    PG7, optional G1/2-inch, G1/4-inch by means of reducer
  • Housing material
    Polycarbonate, UL94-V0
  • Material sensor
    MS58, nickel-plated (optional stainless steel available)
  • Compressive strength
    10 bar
  • Housing material
    Polycarbonate, UL94-V0
  • Housing dimensions
    80 mm x 113 mm x 60 mm
  • Power supply
    20 ... 30 V DC
  • Electrical connection
    9 terminals (max. 1.5 mm²)
  • Power consumption max
    5 VA
  • Current and contact load capacity
    175 V AC/DC, 0,25 A
  • Minimum switching capacity
    10 mA, 5 V DC
  • Ambient temperature
    -20 ... 60°C
  • Optimal run-in distance
    >10 DN
  • Optimal run-out distance
    >5 DN
  • Temperature gradient
    30K/min
  • Certificates
    CE
  • Country of origin
    Germany
  • Customs tariff number
    90 26 80 20
  • HS Code
    90 26 80

Customer Reviews

Based on 4 reviews
75%
(3)
25%
(1)
0%
(0)
0%
(0)
0%
(0)
A
Andreas Jacobi
Exhaust air monitoring test bench

Use the stainless steel version in approx. 320°C air. Quickly installed and set up and in constant use ever since. Reliable and robust - just as expected!

G
Georg T.

Super device. Flow measurement works perfectly and top service from the team. We initially had difficulties, which we were able to resolve quickly in a video call.
The only improvement from my point of view: the device reliably detects the flow, but not the direction of flow. That would be another very helpful enhancement.
Otherwise, a top device with an excellent price-performance ratio

F
Felix Herberger
Simple operation and reliable use

Have been using the predecessor RLSW8 for many years. Much easier to set up with the RLSW 9 - keep up the good work!

M
Markus S.
Top device!

We have been using the measuring device for years. Now significantly upgraded with the new design!

The RLSW®9: The latest generation of our volumetric flow meters

RLSW9 volumetric flow meter for measuring the flow of gases up to 350°C

From €369,80

Volume flow and air velocity measuring device with linear analog output in control quality (0 ... 10 V & 4 ... 20 mA) and switch

Suitable for media temperatures up to 350°C

Measured value display via LCD, LED strip and alarm light

Freely scalable measuring range m/s, m³/h, l/min

S ensitive and fast airflow detection up to 30 m/s, optionally up to 200 m/s

Sensor available in nickel-plated brass (standard), stainless steel or Teflon

Exemplary areas of application: Measurement and control of air flows, building technology, PLC, filter monitoring, extraction and extruder systems, exhaust gases and test benches

Availability

Power consumption

Specification Response time (s)

Minimum pipe diameter

Measuring range temperature Filter

HS Code

90 26 80

Output power min.

Moisture resolution

Analog output specification

0 ... 10 V, linear | load: 0.4 kOhm, 4 ... 20 mA, linear | load: 0.4 kOhm, Linearity error: ±1% of measuring range end value / ±0.5K

Product type Flow

Sensor protection class

IP67

Immersion depth

50, 130, 165, 300, 400, 500, Special lengths on request

Accuracy of the atmospheric pressure

Weight

Insulation resistance

Material connection head

Material sensor

MS58, nickel-plated (optional stainless steel available)

Response time

Enclosure protection class

Type of sensor element

Ambient temperature

-20 ... 60°C

ATEX certification

Fastening strap specification

Housing dimensions

80 mm x 113 mm x 60 mm

Device type

Compact device including sensor (permanently mounted), Compact device including sensor (remote)

Device type

Compact flow device

Sensor cable length

Conformity

Housing material

Polycarbonate, UL94-V0

Temperature measuring range

Temperature measuring accuracy

Product type Temperature

Silver level

Ambient temperature Device

Operating pressure

Medium

Gases

Pressure measuring range

Product type Print

Test mark

Switching differential

Switching capacity

Switching point

Stepless adjustment (software or potentiometer)

Operating voltage

Digital output

Own consumption

Measuring range CO₂

Measuring accuracy relative humidity

Product type Humidity

Reaction time measurement Co.

Power supply

20 ... 30 V DC

Manufacturer

Product type HVAC

Analog signal

Power consumption max

5 VA

Maximum pressure

Display

Electrical connection

9 terminals (max. 1.5 mm²)

Operating temperature

Product type fill level

Relay output specification

Load resistance

Ambient humidity

Ambient temperature Maximum Celsius

Ambient temperature (min. °C)

Compressive strength

10 bar

Media temperature

Product type

Process connection

PG7, optional G1/2-inch, G1/4-inch by means of reducer

Temperature gradient

30K/min

Measuring resistor

Differential pressure max

Accuracy of the output signal LCD Modbus

Flow measuring range

0,1 ... 30 m/s (optionally available up to 200 m/s)

Signal output

Process connection 1

Switching function with flow

Signal display with flow

Signal output flow

Analog output

Notes

Minimum switching capacity

10 mA, 5 V DC

Optimum run-out distance

Optimum run-in distance

Reproducibility of the output signal

Signal display circuit

Current and contact load capacity

175 V AC/DC, 0,25 A

Power supply tolerance

Overvoltage category

Pollution class

Analog input_CO_

Digital input

Measuring range relative humidity

Potentiometer

Potentiometer output

Scale range

Analog input

Analog input_CO2

Installation depth

Digital outputs

Digital inputs

Error inputs

Ambient temperature1

Color

Output signal

Switching output, analog output

Recommended cable cross-section

Signal output Sensor short circuit

Fault-specific error codes in the LCD, 4 mA, Relay drops out

Signal output sensor break

Fault-specific error codes in the LCD, 4 mA, Relay drops out

Outside diameter

Inner diameter

Thread

Temperature range

Lining

Diameter

Flow measurement accuracy

±5% of full scale value, Reproducibility ±2% of full scale value

Setting range

Sensor response length

Capillary tube length

Protection class

Material

Measuring accuracy pressure relative

Temperature compensation

Country of origin

Germany

Vacuum resistance

Hysteresis

Repeatability

Material contact

Bursting pressure

Measuring range atmospheric pressure

Measuring range pressure V2

Short-circuit protection

Max Bürde

Reverse polarity protection

Accuracy of VOC measurement

Measuring range VOC

Media compatibility

Overload pressure

Alarm

Measuring range VOC1

Relay output

Power (kW)

Heat dissipation

Minimum load

Supply output

Cable trenches

Storage temperature

Fuse

Measuring accuracy_CO_

Front cover

Interface

Power supply

Efficiency

Long-term stability

Preset switching point

Customs tariff number

90 26 80 20

Pulley

Media temperature Max

Media temperature min

Show product