Evaluation unit airflow monitor NLSW45-6 SIL2 for environments up to 250°C, with SIL2 certification
Description
Description
✅ Flow monitoring with SIL2 certification in accordance with IEC 62061 (corresponds to performance level d in accordance with EN ISO 13849-1)
✅ Safely and reliably monitor hot air flows up to 250°C (monitoring up to 400°C possible with the NLSW®45-6.1 SIL2 evaluation unit)
✅ Large measuring range from 0.1 ... 30 m/s, quick and easy commissioning
With switching output (relay)
Developed for demanding industrial applications: IP65
✅ Associated flow sensor (available separately): Sensor F8 SIL2 250°C; due to the required redundancy, an evaluation unit always includes 2 flow sensors
✅ Areas of application: Monitoring of heating coils, drying systems, industrial ovens (e.g. EN1539), granulate dryers, surface technology systems, thermal process technology
Evaluation unit air flow monitor NLSW45-6 SIL2 for environments up to 250°C, with SIL2 certification - 230 V AC is in stock and will be shipped as soon as it is available again
Immediately available from stock
Availability for pickups could not be loaded
Specification
Specification
-
MediumGases
-
Device typeFlow evaluation unit for switch cabinet installation, or installation at the measuring point
-
Flow measuring range0.1 ... 30 m/s
-
Media temperature-20 ... 250°C
-
DisplayLED (voltage & switching point)
-
Switching pointStepless adjustment (potentiometer)
-
Protection class evaluation unitIP65
-
Special features2 sensors required (SIL2)
-
Output signalSwitching output
-
Switching output specification2 changeover contacts (per channel)
-
Signal output sensor breakRelay drops out
-
Signal output Sensor short circuitRelay drops out
-
Relay output specification2 changeover contacts (per channel)
-
Housing materialPolyamide (UL94V-0)
-
Housing materialPolyamide (UL94V-0)
-
Housing dimensions85 mm x 165 mm x 55 mm
-
AssemblyMounting set included, Mounting on DIN rail optional
-
Power supply24 V AC/DC ±10%, 230 V AC ±5%
-
Electrical connectionTerminal strip
-
Power consumption max5 VA
-
Recommended cable cross-section2.5 mm²
-
Current and contact load capacity250 VAC, 8 A, 2 kVA
-
Minimum switching capacity10 mA, 5 V DC
-
Ambient temperature-20 ... 60°C
-
CertificatesCE
-
SIL levelSIL2
-
Country of origin
-
Customs tariff number
-
HS Code